Description: <12 Inch> Description:Portable Multi-parameter Patient Monitor is adaptable to adult, pediatric and neonatal usage. It can monitor vital signals as ECG, Respiratory Rate, SpO2, NIBP, TEMP and IBP.It integrates parameter measuring modules, display and recorder in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient.Features:12" high resolution color TFT LCD display.6 Standard parameters:ECG, RESP, NIBP, SPO2, TEMP, PR.Can be arbitrarily set the alarm limit, automatic sound and light alarm.The back of the machine is designed with a storage box, which can put some accessories,convenient for doctors use.Drug solubility calculation function, Arrhythmia analysis function.Built-in lithium battery,AC and DC,can provide long-term monitoring after power failure.Widely used in the Department of internal medicine, Dental practices (both pediatric and adult), oral surgery centers surgery, operation room,obstetrics and Gynecology, pediatrics, emergency center,ICU,CCU. Specification:ECGLead Mode:5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)Lead selection:I, II, III, avR, avL, avF, V,Waveform:2 chLead mode:3 Leads ( R, L, F or RA, LA, LL)Lead selection:I, II, III,Waveform:1 chGain:´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV, autoHR and Alarm Range: Adult:15 ~ 300 bpmNeo/Ped:15 ~ 350 bpmAccuracy:± 1% or ± 1bpm,which greatResolution:1 bpmSensitivity:> 200 (uV P-P)Differential Input Impedance:> 5 MΩRESPARATION:Method:Impedance between R-F(RA-LL)Differential Input Impedance:>2.5 MΩMeasuring Impedance Range:0.3~5.0ΩBase line Impedance Range:0 – 2.5 KΩBandwidth:0.3 ~ 2.5 HzResp. RateMeasuring and Alarm Range Adult:0 ~ 120 rpmNeo/Ped:0 ~ 150 rpmResolution:1 rpmAccuracy:±2 rpmApean Alarm:10 ~ 40 SNIBPMethod:OscillometricMode:Manual, Auto, STATMeasuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)Measuring Period in STAT Mode:5 MinPulse Rate Range:40 ~ 240 bpmAlarm Type:SYS, DIA, MEANMeasuring and alarm range: Adult ModeSYS :40 ~ 270 mmHgDIA :10 ~ 215 mmHgMEAN:20 ~ 235 mmHgPediatric ModeSYS:40 ~ 200 mmHgDIA:10 ~ 150 mmHgMEAN:20 ~ 165 mmHgNeonatal ModeSYS:40 ~ 135 mmHgDIA:10 ~ 100 mmHgMEAN:20 ~ 110 mmHgOverpressure ProtectionAdult Mode:297±3 mmHgPediatric Mode:240±3 mmHgNeonatal Mode:147±3 mmHgSpO2Measuring Range:0 ~ 100 %Alarm Range:0 ~ 100 %Resolution:1 %Accuracy: 70% ~ 100% ±2 %0% ~ 69% unspecifiedActualization interval:about 1 Sec.Alarm Delay:10 Sec.Pulse RateMeasuring and Alarm Range:0~254bpmResolution:1bpmAccuracy:±2bpmI.5TEMP measurement:Channel:1Measuring and Alarm Range:0 ~ 50 °CResolution:0.1°CAccuracy:±0.1°CActualization interval:about 1 Sec.Average Time Constant:< 10 Sec.Package List:1×Patient Monitor1×EKG Lead wire1×NIBP Cuff1×NIBP Extension Cable1×SpO2 Sensor1×Temp Sensor1×Ground Cable5×Electrode2×Fuse1×User Manual(CD)===================================================================================================<8 Inch> Description:Portable Patient Monitor is adaptable to adult, pediatric and neonatal usage. It can monitor vital signals as ECG, Respiratory Rate, SpO2, NIBP, TEMP and IBP. It integrates parameter measuring modules, display and recorder in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient. Large high-resolution display provides clear view of 5 waveforms and full monitoring parameters.Features:8 inch TFT color screenExquisite design suitable to moving operation Various interfaces: standard screen, trend screen, oxyCRG screen, NIBP list screen, big front screen.Real-time S-T segment analysis, pace-maker detection. Built-in rechargeable lithium battery, convenient for patient moving. Suitable for adult, pediatric and neonatal patientStandard Configuration:SpO2, PR, NIBP, ECG, RESP, TEMPTechnical Parameters:ECG:Lead Mode:5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)Lead selection:I, II, III, avR, avL, avF, V,Waveform:2 chGain:2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mVHeart Rate:15-300BPM(Adult) 15-350BPM(Neonatal)Accuracy:± 1% or ± 1bpm,which greatResolution:1 bpmST measurement Range:-2.0-+2.0mVSweep Speed:12.5 mm/s,25mm/s,50mm/sAlarm:AvailableReview:AvailableRESP:Method Impedance between R-F(RA-LL)Measuring Range:Adult 0 ~ 120 rpm,Neo/Ped 0 ~ 150 rpmResolution:1 rpmAccuracy:±2 rpmNIBP:Method:OscillometricMode:Manual, Auto, STATMeasuring and alarm range Adult ModeSYS:40 ~ 270 mmHgDIA:10 ~ 215 mmHgMEAN:20 ~ 235 mmHgPediatric ModeSYS:40 ~ 200 mmHgDIA:10 ~ 150 mmHgMEAN:20 ~ 165 mmHgNeonatal ModeSYS:40 ~ 135 mmHgDIA:10 ~ 100 mmHgMEAN:20 ~ 110 mmHgResolution:1mmHgAccuracy:+-5mmHgSpO2:Measuring Range:0 ~ 100 %Alarm Range:0 ~ 100 %Resolution:1 %Accuracy:70% ~ 100% ±2 %Actualization interval:about 1 Sec.Alarm Delay:10 Sec.Pulse Rate :0~254bpmResolution:1bpmAccuracy:±2bpmTemperature:Measuring and Alarm Range:0 ~ 50 CResolution:0.1CAccuracy:0.1CActualization interval:about 1 Sec.Average Time Constant:< 10 Sec.Package List:Patient monitorTemperature probeECG lead cableECG electrodeAdult NIBP cuffNIBP extension tubeAdult fingertip SpO2 probePower cordUser Manual FDA Disclaimer: Statement:The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.This item has been cleaned and treated according to the manufacturer's instructions.Ashley-China-Beijing-86-15360879313The Fingertip Pulse Oximeter is certified with the US FDA 510K No. K070371, the CE & TUV of Eureope and it is on the Australian Register of Therapeutic Goods (ARTG) with the code 136606.The Powered Surgical Instrument / Speed 808 System is certified with the US FDA 510(k) Number:K132989The Powered Surgical Instrument / Hair Remove Device is certified with the US FDA 510(k) Number:K180353The Powered Surgical Instrument / Hair Remove System is certified with the US FDA 510(k) Number:K141973massager, vacuum, light induced heating / Slimming Treatment Device is certified with the US FDA 510(k) Number:K161892 Ultrasound ,Ultrasonic Treatment Device is certified with the US FDA 510(k) Number:K161892This item has been cleaned and treated according to the manufacturer's instructions.
Price: 409 USD
Location: Cranbury, New Jersey
End Time: 2024-10-09T07:12:12.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: Carejoy
Expiration Date: Brand New
Number of Channels: 1
Technology: Digital
Model: RPM-9000C4/RPM-9000F
MPN: Does not apply
Features: Battery Operated, Handheld, Printer
Country/Region of Manufacture: China
Monitor Parameters: Blood Pressure - NIBP, ECG, O2 - SpO2, Respiratory Rate, Temperature, PR
Intended Use/Discipline: Cardiology, Emergency Medicine, Family Medicine
Available Variations
Color: 12 inch
Price: 509 USD
Available Quantity: 2
Quantity Sold: 0
Color: 8 inch
Price: 409 USD
Available Quantity: 2
Quantity Sold: 0